AAgEquipmentDirectory

Home / Guides / Maintenance & repair

Fixing Hydraulic Leaks on Loaders and Implements

Control stored energy before inspection

Park safely, lower the attachment and follow machine-specific shutdown and depressurization instructions. Keep clear of any raised load or unsupported structure and never use skin to find a leak. High-pressure fluid injection requires emergency medical attention even if the skin wound looks minor.

Give the hose shop the exact specification

Have trained personnel identify the leaking component and compatible replacement. Provide pressure and fluid compatibility requirements, size, fitting standards, orientation and routing. Confirm protection from rubbing and motion. After the repair have an approved functional test performed with people clear of the machine.

Example

A hose that looks the right length can still fail early if its fitting angle forces a twist whenever the loader reaches full travel.

Put it into practice

Write the model, machine side and exact operating position where the leak appeared. Give a technician that record before a fitting is removed.

References

Penn State Extension farm equipment and structures safety, HSE guidance on high-pressure hydraulic fluid injection.

Find equipment and support

Related guides