Section Control for Sprayers and Planters
Measure the machine’s geometry
Enter actual widths, offsets and a clean field boundary. Check section or row configuration and GPS source. Adjust manufacturer-provided timing values using an approved test, then compare placement at typical speeds and entry angles. A map alone can hide lag between a command and physical delivery.
Check corners and headlands
Look for overlap or gaps in short points and when leaving previously treated strips. Use seed observations or clean-water testing as appropriate. Review how the controller behaves after a signal interruption. Record offsets separately for every tractor and implement combination.
Example
A lag of half a second at six miles per hour shifts a physical result about 4.4 feet before other offsets are considered.
Put it into practice
Label the saved settings by tractor, attachment and speed. Verify physical placement before leaving the test field.
References
University of Georgia Extension sprayer calibration guidance, AEF ISOBUS compatibility database and supported functions.